Trenchless Solutions operate a wide range of Guided Auger Boring systems, pipe sizes range from 90mmØ up to 1016mmØ, with jacking forces from 10te to 150te working from 2.0m long pits or 2.1mØ standard round shafts. These optically guided systems are the ideal No-Dig solution for installing new gravity pipelines or purely where accuracy is critical.
A variety of pipe materials can be installed i.e. Naylor Denlok Jacking pipe, steel casings, PE and Hobas GRP Jacking pipe in a wide range of ground conditions where minimal settlement is crucial up to distances of 100m, under waterways, roads, railways, existing structures, congested areas and environmentally sensitive areas.
Prior to pipe installation, a pilot bore is driven to line/level and all aspects of this method fully support the ground during installation, the cut spoil is conveyed by continuous flight auger back to the work pit.